(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
A wide variety of standard and configurable components for factory automation engineers in industries such as automotive, semiconductor, packaging, medical and many more.
A good selection of accessories such as screws, bolts, washers and nuts that you may need for your daily engineering usage.
Browse industrial materials ranging from heat insulating plates, sponges, to metal and plastic materials in different sizes to meet your various applications.
A wide variety of wiring parts for connecting and protecting control and PC parts including Connectors, Cables, Electric Wires, Crimping Terminals and more.
A wide variety of controls and PC parts for electrical engineers including Controls, Powers, PC parts and more.
A wide variety of cutting tools for many uses and work materials including End Mills, Drills, Cutters, Reamers, Turning Tools and more.
A wide variety of tools and supplies used in processing including Machine Tools, Measurement Tools, Grinding and Polishing Supplies and more.
A wide variety of goods used in shipment, material handling and warehouse including Tape supplies, Stretch film, Truck, Shelf, Crane and more.
A large variety of goods for every kind of factories and offices including Protection items, Cleaning supplies, sanitations, office supplies and more.
A large variety of items used in R&D and Clean Room including research Equipment, Laboratory Essentials, Analysis Supplies, Clean Environment-Related Equipment and more.
Choose from thousands of standard stamping die components including Punch & Die, Gas Springs, Guide Components, Coil Springs and many more.
Browse our wide variety of mold components including Ejector Pins, Sleeves, Leader Components, Sprue Bushings and many more.
Browse our injection molding components including Heating Items, Couplers, Hoses and more.
Days to Ship |
|
---|
CSA Standard Compliant, 5-Port Solenoid Valve, Pilot Operated, Metal Seal, VFS5000
SMC
CSA standard compliant, 5-port solenoid valve pilot type metal seal non-plug-in type.
Days to Ship: | 21 Day(s) or more |
---|
CSA Standard Compliant, 5-Port Solenoid Valve, Pilot Operated, Metal Seal, VFS6000
SMC
CSA standard compliant, 5-port solenoid valve pilot type metal seal non-plug-in type.
Days to Ship: | Quote |
---|
CSA Standard Compliant, 5-Port Solenoid Valve, Pilot Operated, Elastic Seal, VFR3000
SMC
CSA standard compliant, 5-port solenoid valve pilot type elastic seal non-plug-in type.
Days to Ship: | 21 Day(s) or more |
---|
CSA Standard Compliant, 5-Port Solenoid Valve, Pilot Operated, Elastic Seal, VFR4000
SMC
CSA standard compliant, 5-port solenoid valve pilot type elastic seal non-plug-in type.
Days to Ship: | 21 Day(s) or more |
---|
ATEX Directive 5-Port Solenoid Valve, 56-VQC1000 Series, ATEX Category 3
SMC
[What is ATEX Directive?]
Since July 1, 2003, it has been mandatory within the EU to comply with the ATEX Directive for equipment used in potentially explosive atmospheres.
■CE mark and ATEX
The ATEX Directive is now part of the CE mark, which incorporates the traditional European explosion-proof standard.
■Purpose of ATEX Directive
The main purposes of ATEX are:
・ Prevention of electrostatic charge
・ Ignition prevention of sparks caused by friction, impact, and abrasion
・ Ignition prevention due to temperature rise due to the same as above
・ The responsibility lies with the manufacturer
・ Certification by zone/category
■Zone/Category
In ATEX, the objects to be applied are classified into categories for each dangerous place (zone).
・ Zone 0: Category 1
Possibility of explosive atmosphere (Zone): Continuous or long time > 1,000 hours/year
・ Zone 1: Category 2
Possibility of explosive atmosphere (Zone): occasionally 10 to 1,000 hours/year
・ Zone 2: Category 3
Possibility of explosive atmosphere (Zone): Less likely, short time < 10 hours/year
Days to Ship: | 21 Day(s) or more |
---|
ATEX Directive 5-Port Solenoid Valve, 56-VQC2000 Series, ATEX Category 3
SMC
[What is ATEX Directive?]
Since July 1, 2003, it has been mandatory within the EU to comply with the ATEX Directive for equipment used in potentially explosive atmospheres.
■CE mark and ATEX
The ATEX Directive is now part of the CE mark, which incorporates the traditional European explosion-proof standard.
■Purpose of ATEX Directive
The main purposes of ATEX are:
・ Prevention of electrostatic charge
・ Ignition prevention of sparks caused by friction, impact, and abrasion
・ Ignition prevention due to temperature rise due to the same as above
・ The responsibility lies with the manufacturer
・ Certification by zone/category
■Zone/Category
In ATEX, the objects to be applied are classified into categories for each dangerous place (zone).
・ Zone 0: Category 1
Possibility of explosive atmosphere (Zone): Continuous or long time > 1,000 hours/year
・ Zone 1: Category 2
Possibility of explosive atmosphere (Zone): occasionally 10 to 1,000 hours/year
・ Zone 2: Category 3
Possibility of explosive atmosphere (Zone): Less likely, short time < 10 hours/year
Days to Ship: | 21 Day(s) or more |
---|
ATEX Directive 5-Port Solenoid Valve, 56-VQC4000 Series, ATEX Category 3
SMC
[What is ATEX Directive?]
Since July 1, 2003, it has been mandatory within the EU to comply with the ATEX Directive for equipment used in potentially explosive atmospheres.
■CE mark and ATEX
The ATEX Directive is now part of the CE mark, which incorporates the traditional European explosion-proof standard.
■Purpose of ATEX Directive
The main purposes of ATEX are:
・ Prevention of electrostatic charge
・ Ignition prevention of sparks caused by friction, impact, and abrasion
・ Ignition prevention due to temperature rise due to the same as above
・ The responsibility lies with the manufacturer
・ Certification by zone/category
■Zone/Category
In ATEX, the objects to be applied are classified into categories for each dangerous place (zone).
・ Zone 0: Category 1
Possibility of explosive atmosphere (Zone): Continuous or long time > 1,000 hours/year
・ Zone 1: Category 2
Possibility of explosive atmosphere (Zone): occasionally 10 to 1,000 hours/year
・ Zone 2: Category 3
Possibility of explosive atmosphere (Zone): Less likely, short time < 10 hours/year
Days to Ship: | Quote |
---|
5-Port Solenoid Valve, Base Mounted Type, Clean, 10-S0700
SMC
[10-Series, Clean Series]
Suitable for clean environment
Prevents dust generation in the cleanroom
Days to Ship: | 21 Day(s) or more |
---|
5-Port Solenoid Valve, Base Mounted, Clean, 10-VQ1000
SMC
[10-Series, Clean Series]
Suitable for clean environment
Prevents dust generation in the cleanroom
Days to Ship: | Quote |
---|
5-Port Solenoid Valve, Base Mounted, Clean, 10-VQ2000
SMC
[10-Series, Clean Series]
Suitable for clean environment
Prevents dust generation in the cleanroom
Days to Ship: | Quote |
---|
5-Port Solenoid Valve, Plug-in Type, Clean Series, 10-SZ3000 Series
SMC
[10-Series, Clean Series]
Suitable for clean environment
Prevents dust generation in the cleanroom
Days to Ship: | Quote |
---|
5-Port Solenoid Valve Non-Plug-in Type Clean Series 10-SZ3000 Series
SMC
[10-Series, Clean Series]
Suitable for clean environment
Prevents dust generation in the cleanroom
Days to Ship: | Quote |
---|
Guide integrated cylinder with valve Valve for MVGQ series (For ø25 to ø63)
SMC
Guide integrated cylinder with valve MVGQ series, valve for ø25 to ø63.
Days to Ship: | 21 Day(s) or more |
---|
Guide integrated cylinder with valve Valve for MVGQ series (For ø12 to ø20)
SMC
Guide integrated cylinder with valve MVGQ series, valve for ø12 to ø20.
Days to Ship: | 21 Day(s) or more |
---|
5-Port Solenoid Valve, Plug-in SY5000/7000 Series Valve With Pressure Sensor
SMC
[Features]
・ Output pressure detection of 4 (A) and 2 (B) ports is possible
・ Detects abnormalities such as switching failure, response delay, back pressure interference, and pressure drop
・ Identification of abnormal parts such as actuators and solenoid valves
・ By mounting the pressure switch directly on the solenoid valve, space can be saved and installation man-hours can be reduced
Days to Ship: | Quote |
---|
CSA Standard Compliant, 5-Port Pilot Operated Solenoid Valve, Elastic Seal, VF1000/3000/5000
SMC
[CSA Standard]
The CSA standard is a safety standard for electrical products, medical devices, machines, appliances, etc., in Canada.
Established in 1919 as a non-profit, non-governmental standards body.
The Canadian Standard Association, a group organization of CSA, creates the standard,
and CSA International conducts product testing and certification services.
Standard Price: | MYR 556.87- |
---|---|
Days to Ship: | 27 Day(s) or more |
Brand |
---|
Product Series |
CAD |
Days to Ship |
Number of Ports |
Application |
Switching Type |
Voltage |
Number of Solenoids |
Mounting Orientation |
Pipe Port Type |
Specifications |
Status at Power Off |
Plumbing Thread Nominal |
Plumbing |
Applicable Cylinder Dia.(Ø) |
Type |
Driving Type |
Connecting Tube Diameter |
Pressure Rating(MPa) |
Seal Type |
CV Value |
Pilot Air Supply |
Brand | SMC | SMC | SMC | SMC | SMC | SMC | SMC | SMC | SMC | SMC | SMC | SMC | SMC | SMC | SMC | SMC |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Product Series | CSA Standard Compliant, 5-Port Solenoid Valve, Pilot Operated, Metal Seal, VFS5000 | CSA Standard Compliant, 5-Port Solenoid Valve, Pilot Operated, Metal Seal, VFS6000 | CSA Standard Compliant, 5-Port Solenoid Valve, Pilot Operated, Elastic Seal, VFR3000 | CSA Standard Compliant, 5-Port Solenoid Valve, Pilot Operated, Elastic Seal, VFR4000 | ATEX Directive 5-Port Solenoid Valve, 56-VQC1000 Series, ATEX Category 3 | ATEX Directive 5-Port Solenoid Valve, 56-VQC2000 Series, ATEX Category 3 | ATEX Directive 5-Port Solenoid Valve, 56-VQC4000 Series, ATEX Category 3 | 5-Port Solenoid Valve, Plug-in Type, Clean Series, 10-SZ3000 Series | 5-Port Solenoid Valve Non-Plug-in Type Clean Series 10-SZ3000 Series | Guide integrated cylinder with valve Valve for MVGQ series (For ø25 to ø63) | Guide integrated cylinder with valve Valve for MVGQ series (For ø12 to ø20) | 5-Port Solenoid Valve, Plug-in SY5000/7000 Series Valve With Pressure Sensor | CSA Standard Compliant, 5-Port Pilot Operated Solenoid Valve, Elastic Seal, VF1000/3000/5000 | |||
CAD |
|
| ||||||||||||||
Days to Ship | 21 Day(s) or more | Quote | 21 Day(s) or more | 21 Day(s) or more | 21 Day(s) or more | 21 Day(s) or more | Quote | 21 Day(s) or more | Quote | Quote | Quote | Quote | 21 Day(s) or more | 21 Day(s) or more | Quote | 27 Day(s) or more |
Number of Ports | 5-Port Valve | 5-Port Valve | 5-Port Valve | 5-Port Valve | 5-Port Valve / Dual 3-Port Valve | 5-Port Valve / Dual 3-Port Valve | 5-Port Valve | 5-Port Valve / Dual 3-Port Valve | 5-Port Valve | 5-Port Valve | 5-Port Valve | 5-Port Valve | 5-Port Valve | 4-Port Valve | 5-Port Valve | 5-Port Valve |
Application | Single Use / Unit for Manifold Mounting | Single Use / Unit for Manifold Mounting | Single Use / Unit for Manifold Mounting | Single Use / Unit for Manifold Mounting | Unit for Manifold Mounting | Unit for Manifold Mounting | Unit for Manifold Mounting | Unit for Manifold Mounting | Unit for Manifold Mounting | Unit for Manifold Mounting | Unit for Manifold Mounting | Unit for Manifold Mounting | Unit for Manifold Mounting | Unit for Manifold Mounting | Unit for Manifold Mounting | Single Use / Unit for Manifold Mounting |
Switching Type | 2-Position Exhaust / 3-Position Closed Center / 3-Position Exhaust Center / 3-Position Pressure Center / Others | 2-Position Exhaust | 2-Position Exhaust / 3-Position Closed Center / 3-Position Exhaust Center / 3-Position Pressure Center | 2-Position Exhaust / 3-Position Closed Center / 3-Position Exhaust Center / 3-Position Pressure Center | 2-Position Exhaust / 3-Position Closed Center / 3-Position Exhaust Center / 3-Position Pressure Center / Others | 2-Position Exhaust / 3-Position Closed Center / 3-Position Exhaust Center / 3-Position Pressure Center / Others | 2-Position Exhaust / 3-Position Closed Center / 3-Position Exhaust Center / 3-Position Pressure Center | 2-Position Exhaust / Others | 2-Position Exhaust / 3-Position Closed Center / 3-Position Exhaust Center | 2-Position Exhaust / 3-Position Closed Center / 3-Position Exhaust Center | 2-Position Exhaust / 3-Position Closed Center / 3-Position Exhaust Center / 3-Position Pressure Center / Others | 2-Position Exhaust / 3-Position Closed Center / Others | 2-Position Exhaust | 2-Position Normally Closed | 2-Position Exhaust / 3-Position Closed Center | 2-Position Exhaust / 3-Position Closed Center / 3-Position Exhaust Center / 3-Position Pressure Center |
Voltage | DC24V / AC100V / AC220V / 110/120 V AC | DC24V / AC100V / AC200V / 110/120 V AC | DC24V / AC100V / AC200V / AC220V / 110/120 V AC | DC24V / AC100V / AC200V / 110/120 V AC | DC24V | DC24V | DC24V | DC12V / DC24V | DC24V | DC24V | DC12V / DC24V | DC24V | DC12V / DC24V / AC100V / AC110V / AC200V / AC220V | DC12V / DC24V / AC100V / AC200V / AC220V / DC5V | DC24V | DC24V / AC100V / AC200V / AC220V / 110/120 V AC |
Number of Solenoids | Single / Double | Single / Double | Single / Double | Single / Double | Single / Double | Single / Double | Single / Double | Single / Double | Single / Double | Single / Double | Single / Double | Single / Double | Single / Double | Single / Double | Single / Double | Single / Double |
Mounting Orientation | Direct / Manifold Base | Direct / Manifold Base | Direct / Manifold Base | Direct / Manifold Base | Manifold Base | Manifold Base | Manifold Base | Manifold Base | Manifold Base | Manifold Base | Manifold Base | Manifold Base | Manifold Base | Manifold Base | Manifold Base | Direct / Manifold Base |
Pipe Port Type | Rc (R) / NPT / NPTF / G | Rc (R) / NPTF | Rc (R) / NPT / G | Rc (R) / NPT / G | - | - | - | - | - | - | One-Touch Plumbing / Barbed Couplers | One-Touch Plumbing | - | - | One-Touch Plumbing | Rc (R) / NPT / G |
Specifications | Lubrication Free | Lubrication Free | Lubrication Free | Lubrication Free | Drip-Proof / Lubrication Free | Drip-Proof / Lubrication Free | Drip-Proof / Lubrication Free | Standard / Lubrication Free | Lubrication Free / Cleanroom | Lubrication Free / Cleanroom | Lubrication Free | Standard | Lubrication Free | Lubrication Free | Lubrication Free | Lubrication Free |
Status at Power Off | Self-Retaining / Self-Recovery (Spring Return) | Self-Retaining / Self-Recovery (Spring Return) | Self-Retaining / Self-Recovery (Spring Return) | Self-Retaining / Self-Recovery (Spring Return) | Self-Retaining / Self-Recovery (Spring Return) | Self-Retaining / Self-Recovery (Spring Return) | Self-Retaining / Self-Recovery (Spring Return) | Self-Retaining / Self-Recovery (Spring Return) | Self-Retaining / Self-Recovery (Spring Return) | Self-Retaining / Self-Recovery (Spring Return) | Self-Retaining / Self-Recovery (Spring Return) / Self-Recovery (Pressure Differential Return) | Self-Retaining / Self-Recovery (Spring Return) / Self-Recovery (Pressure Differential Return) | Self-Recovery (Spring Return) | Self-Recovery (Pressure Differential Return) | Self-Retaining / Self-Recovery (Spring Return) / Self-Recovery (Pressure Differential Return) | Self-Retaining / Self-Recovery (Spring Return) |
Plumbing Thread Nominal | 1/2 ~ 3/8 | 1 ~ 3/4 | 1/4 ~ 3/8 | 1/2 ~ 3/8 | - | - | - | - | - | - | M5 | - | - | - | - | 1/2 ~ 3/8 |
Plumbing | Sub-Base Plumbing | Sub-Base Plumbing | Sub-Base Plumbing | Sub-Base Plumbing | Sub-Base Plumbing | Sub-Base Plumbing | Sub-Base Plumbing | Sub-Base Plumbing | Sub-Base Plumbing | Sub-Base Plumbing | Direct Plumbing | Direct Plumbing | Sub-Base Plumbing | Sub-Base Plumbing | Direct Plumbing | Direct Plumbing / Sub-Base Plumbing |
Applicable Cylinder Dia.(Ø) | - | - | 40 to 140 ~ 40 to 200 | 50 to 300 ~ 80 to 300 | 80 or Less | 100 or Less | 200 or less | - | 80 or Less | 100 or Less | - | - | 40 or less ~ 50 or Less | 20 or Less | 125 or less | 80 or Less ~ 200 or less |
Type | Solenoid Valves | Solenoid Valves | Solenoid Valves | Solenoid Valves | Solenoid Valves | Solenoid Valves | Solenoid Valves | Solenoid Valves | Solenoid Valves | Solenoid Valves | Solenoid Valves | Solenoid Valves | Solenoid Valves | Solenoid Valves | Solenoid Valves | Solenoid Valves |
Driving Type | Pilot Type Spool | Pilot Type Spool | Pilot Type Spool | Pilot Type Spool | Pilot Type Spool | Pilot Type Spool | Pilot Type Spool | Pilot Type Spool | Pilot Type Spool | Pilot Type Spool | Pilot Type Spool | Pilot Type Spool | Pilot Type Spool | Pilot Type Spool | Pilot Type Spool | Pilot Type Spool |
Connecting Tube Diameter | - | - | - | - | - | - | - | - | - | - | Ø4 / Ø6 | Ø4 / Ø6 | - | - | Ø6 | - |
Pressure Rating(MPa) | 0.1 to 1.0 | 0.1 to 1.0 | 02 to 0.9 / 0.1 ~ 0.9 | 02 to 0.9 / 0.1 ~ 0.9 | 0.15 to 0.7 / 0.1 to 0.7 / 0.2 to 0.7 | 0.15 to 0.7 / 0.1 to 0.7 / 0.2 to 0.7 | 0.15 to 1 / 0.2 to 1 | 0.2 to 0.7 | 0.1 to 0.7 / 0.15 to 0.70 / 0.2 to 0.7 / 0.1 to 1.0 | 0.15 to 0.7 / 0.1 to 0.7 / 0.2 to 0.7 / 0.1 to 1.0 | 0.15 to 0.7 / 0.1 to 0.7 / 0.2 to 0.7 | - | 0.15 to 0.7 / 0.1 to 0.7 | 0.15 to 0.7 / 0.1 to 0.7 | 0.15 to 0.7 / 0.1 to 0.7 / 0.2 to 0.7 | 0.15 to 0.7 / 0.1 to 0.7 |
Seal Type | Standard | Standard | Soft Seal | Soft Seal | Standard / Soft Seal | Standard / Soft Seal | Standard / Soft Seal | Soft Seal | Standard / Soft Seal | Standard / Soft Seal | Standard | Standard | Soft Seal | Soft Seal | Standard / Soft Seal | Soft Seal |
CV Value | 3.7 ~ 4.2 | 6.8 | 1.7 ~ 2.2 | 3.2 ~ 4 | 0.16 ~ 0.21 | 0.46 ~ 0.8 | 1.5 ~ 2.1 | 0.09 ~ 0.11 | 0.16 ~ 0.21 | 0.46 ~ 0.55 | 0.14 ~ 0.18 | 0.14 ~ 0.18 | - | - | - | 0.17 ~ 2.4 |
Pilot Air Supply | Internal | Internal | Internal | Internal | Internal | Internal | Internal | Internal | Internal | Internal | Internal | Internal | Internal | Internal | Internal | Internal |
Loading...
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy