(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

  • Kindly be informed that it will be peak period in conjunction with the Chinese New Year festive season. Delivery pickup upon 25 January 2025 estimated would arrive after CNY holidays. Please expect slight delay for orders shipped during this peak season and we thank you for your kind understanding. [Details]
  • Please note that E-Invoice will be sent to our customers by email. For more information, please read News. 

MVVS 100 V or Less with Shield

MVVS 100 V or Less with Shield

Click this image to zoom it.

Move the mouse over the image to zoom

Value Series For Weak-Current Circuit General-purpose Signals Cable

  • Strand Wire
  • Single Shield
  • Less than 100 V

· Color and softness may vary slightly due to manufacturer changes.
* All unit prices are per meter.
Unit Price Calculation Method
[Formula: Last digits of model number (m) x unit price per meter above]
* Color and softness may vary slightly due to manufacturer changes.

PDF

Part Number

Configured Part Number is shown.

Specifications

MVVS 100 V or Less with Shield:Related Image

Model NumberSection Area (mm2)Number of CoresTotal Length *3
or
Specified Length
Model NumberSection Area (mm2)Number of CoresTotal Length *3
or
Specified Length
VAMVVS0.321
~
100
(Specify 1 m
Increment)
·
500
·
1000
3
4
5
6
7
8
10
12
16
0.52
3
4
5
6
7
8
10
0.752
3
4
6
8
1.252
3
4
2.02
3
4


Be sure to read the following precautions when you place an order.
* Length in "m" is included in our model numbers. Always specify quantity as number of units, not as meters.
*1 Stock products are indicated with T or A in the price column at right.
*2 All unit prices above are per meter.
Unit Price Calculation Method [Formula: Last digits of model number (m) x unit price per meter above]
*3 Please note that when ordering 1000 m and 500 m, the order will be delivered as 100 m windings (we cannot accept orders for single cables).

More Information

MVVS 100 V or Less with Shield:Related Image

MVVS 100 V or Less with Shield:Related Image

MVVS 100 V or Less with Shield:Related Image

Specifications
Model NumberSection Area
(mm2)
Number of CoresAWG
Estimated
Size *1
Twisted
Structure
(See Figure)
Number of
Wire Cores
Finished *6
Outer Diameter
(mm)
Approximate
Mass
kg / km
Electrical PropertiesConductorInsulationWire Core
Outer Diameter
Approx. (mm)
SheathSpecificationSample
Provided *4
Allowable Current
A (30°C) *2
Conductor Resistance
Ω / km (20 °C)
Insulation Properties
MΩ km (20 °C)
Withstand Voltage
V / Min
Structure
Pc / mm
Outer Diameter
Approx. (mm)
Plating *3Thickness
(mm)
Material *3Thickness
(mm)
Material *3
VAMVVS

0.3222Core / Layer Stranding25.138463.2550012/0.180.7N/A0.3PVC1.30.9PVC-
335.3434-
4 45.9493-
556.45031-
666.8553-
776.8603-
887.3653-
10108.5752-
12128.7952-
16169.61252-
0.522026.145637.820/0.180.90.31.50.9-
336.4525-
446.9635-
557.46541-
668.0704-
778.0804-
888.8854-
101010.11153-
0.7521826.954825.130/0.181.10.31.70.9-
337.3657-
447.9786-
669.41055-
8810.112551.0-
1.2521627.7771115.150/0.181.50.42.30.9-
338.1959-
449.01148-
2.021428.398149.7937/0.261.80.42.60.9-
339.012212-
449.714811-


*1 The size conversion is for reference only. Refer to the comparison table on >>Click here for details.
*2 The value of allowable current is to be used only as a reference value and is not guaranteed.
*3 How to View Materials
[Plating] Tin... Tin Plated Annealed Copper Wire
[Materials] PVC... Polyvinyl Chloride; PE... Polyethylene-based Material;
P... Polyester-based Material; Fluorine... Various Fluorine Resins; *... Other
*4 Color and softness may vary slightly due to manufacturer changes.
*5 For the outer diameter size of cables, wire sheath (coat), etc., refer to "Finished Outer Diameter" in the table above.
*6 The main difference from the MVVS-A series on is the manufacturer. The specifications are extremely similar: it is an equivalent product. For detailed specification differences, check the Specification Table.


Current Reduction Factor
· At Ambient Temperature
Ambient Temperature (°C)3540455055
Current Reduction Factor0.910.820.710.580.41
Allowable current value indicates the calculated value of 1 cable laid aboveground in ambient temperature of 30°C, and is not a guaranteed value.
If the ambient temperature is 30 °C or above, the above current reduction factor is multiplied by the allowable current.
(Example) Allowable current value 2.0 x 0.82 = 1.64 (A)
when the ambient temperature is 40 °C at 2-core MVVS 0.3 mm2


Wire Core Identification Table
Wire Core No.12345678910111213141516
Insulator ColorBlackWhiteRedGreenYellowBrownBlueGrayOrangeLight BluePinkLight GreenPurpleWhiteWhiteWhite
Color of Identification Line-------------BlackRedGreen
Part Number
VAMVVS-0.3-3-[1-99/1]
VAMVVS-0.3-4-[1-99/1]
VAMVVS-0.3-7-[1-99/1]
VAMVVS-0.3-10-[1-99/1]
VAMVVS-0.3-16-[1-99/1]
VAMVVS-2.0-3-[1-99/1]
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipOverall Length
(m)
Conductor Cross Section
(mm2)
AWG size
(AWG)
Number Of Cores
(Core)
Finished outer diameter
(mm)

-

1 Piece(s) 4 Day(s) or more 1 ~ 990.32235.2

-

1 Piece(s) 4 Day(s) or more 1 ~ 990.32245.5

-

1 Piece(s) 4 Day(s) or more 1 ~ 990.32276.6

-

1 Piece(s) 4 Day(s) or more 1 ~ 990.322107.9

-

1 Piece(s) 4 Day(s) or more 1 ~ 990.322168.8

-

1 Piece(s) 4 Day(s) or more 1 ~ 9921438

Loading...

  1. 1

Basic Information

Rated Voltage For Low Current Circuits Shield Present Sheath (outer coating) color Ash color
Sheath (outer coating) material PVC Insulation body materials PVC Power supply/signal Dual use
Other properties Noise Resistance

Additional Products in this Category