FEATURES  MISUMI MASTER CABLE
●Suitable for fixed wiring, such as control wiring.。
●Uses flexible PVC material that is convenient for wiring.
●With braided shielding, it has excellent anti-interference properties.
●RoHS compliant.
a.Cut-to-length orders: enter requested length in the Length section (up to 100m)
b.Whole roll orders: enter 100 in the Length section.
NOTE:1 roll=100m
· MISUMI may make design changes without notice resulting in color and flexibility variations.

Specification Table




<

Overview/Features

Current Reduction Factor
ShapeSection Area
(mm2)
Number of PairsSpecified LengthAWG
Size
Twisting
Structure
Number of
Wire Cores
Cable
OD
(mm)
Reference
Weight
kg/km
Electrical PropertiesConductorInsulationWire Core
OD
(mm)
Sheath
Maximum allowable current
A(30℃)
Conductor Resistance
Ω/km
(20℃)
Insulation Characteristic
MΩ/km
(20℃)
Maximum Voltage
V/5 minutes
Core Wire Structure
pcs/mm
Outer Diameter
Approx.(mm)
ElectroplatingThickness
(mm)
MaterialThickness
(mm)
Material
MAST-SNTS0.21P1~100
(Can be specified down to 1m increments)
24Twisted Pair24.30294.02931030045/0.080.62Tin0.19PVC1.000.85PVC
2P45.60453.11
3P65.85532.63
4P86.58662.301.00
5P107.06772.14
7P148.05941.61
13P269.591431.34
20P4011.252021.18
25P5012.342541.071.20
0.31P2224.60335.166565/0.080.760.201.150.85
2P46.40593.99
3P66.68693.371.00
4P87.17822.95
5P107.72932.75
7P148.871182.06
13P2610.741851.72
20P4012.932721.511.20
Environmental Temperature(℃)203040506070
Current Reduction Factor1.110.860.710.50.28
Allowable current value indicates the calculated value of 1 cable laid above ground in ambient temperature of 30℃, and is not a guaranteed value.
If the ambient temperature is 30℃ or above, the above current reduction factor is multiplied by the allowable current.




※ Note that the wire core number is “2” when the core number/pair number is marked as 1P.
※ The specification conversion is for reference only. For details, refer to the Line Number Table at >> Click here.
* Maximum allowable current is to be used only as a reference value and is not guaranteed.
※ Material Acronym
[Electroplating] Tin…Tinned Annealed Copper Wire
[Material] PVC…Polyvinyl chloride PE…Polyethylene materials
P…Polyester materials Fluorine…Various fluoro resins
※…Others
※The color and flexibility may vary with manufacturer.
Refer to the website for the latest information.
Product Feature
ItemSpecificationsConditionsRemark
Insulation

Characteristic
Tensile Strength(Lbf/in2)-JIS C3306Test Method:
·JIS C3005
(Mpa)10-
Stretching(%)120-
Tensile Strength after Aging(%)90-
Elongation after Aging(%)75-
Aging Conditions48 Hours at 100℃
Tensile Strength(Lbf/in2)-UL758Test Method:
·Refer to UL758
·UL1061 Compliant
(Mpa)20.7-
Stretching(%)100-
Tensile Strength after Aging(%)70-
Elongation after Aging(%)70-
Aging Conditions 168 Hours at 113℃
Sheath

Characteristics
Tensile Strength(Lbf/in2)-JIS C3306Test Method:
·JIS C3005
(Mpa)10-
Stretching(%)120-
Tensile Strength after Aging(%)85-
Elongation after Aging(%)80-
Aging Conditions48 Hours at 100℃
Tensile Strength(Lbf/in2)-UL758Test Method:
·Refer to UL758
·UL20276 Compliant


·Flame Retardance Test
VW-1 Rated
(Mpa)10.3-
Stretching(%)100-
Tensile Strength after Aging(%)70-
Elongation after Aging(%)45-
Aging Conditions
Part Number
MAST-SNTS-0.2-1P-[1-100/1]
MAST-SNTS-0.2-2P-[1-100/1]
MAST-SNTS-0.2-3P-[1-100/1]
MAST-SNTS-0.2-4P-[1-100/1]
MAST-SNTS-0.2-5P-[1-100/1]
MAST-SNTS-0.2-7P-[1-100/1]
MAST-SNTS-0.2-13P-[1-100/1]
MAST-SNTS-0.2-25P-[1-100/1]
MAST-SNTS-0.3-1P-[1-100/1]
MAST-SNTS-0.3-3P-[1-100/1]
MAST-SNTS-0.3-4P-[1-100/1]
MAST-SNTS-0.3-5P-[1-100/1]
MAST-SNTS-0.3-7P-[1-100/1]
MAST-SNTS-0.3-13P-[1-100/1]
MAST-SNTS-0.3-20P-[1-100/1]
MAST-SNTS-0.3-25P-[1-100/1]
MAST-SNTS-0.5-1P-[1-100/1]
MAST-SNTS-0.5-2P-[1-100/1]
MAST-SNTS-0.5-3P-[1-100/1]
MAST-SNTS-0.5-4P-[1-100/1]
MAST-SNTS-0.5-5P-[1-100/1]
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipConductor Cross Section
(mm2)
Number Of Cores
(Core)
Logarithm AWG size
(AWG)
Finished outer diameter
(mm)

-

1 Piece(s) 11 Day(s) 0.221P24-

-

1 Piece(s) 11 Day(s) 0.242P24-

-

1 Piece(s) 11 Day(s) 0.263P24-

-

1 Piece(s) 11 Day(s) 0.284P24-

-

1 Piece(s) 11 Day(s) 0.2105P24-

-

1 Piece(s) 11 Day(s) 0.2--24-

-

1 Piece(s) 11 Day(s) 0.2-13P24-

-

1 Piece(s) 11 Day(s) 0.25025P24-

-

1 Piece(s) 11 Day(s) 0.321P22-

-

1 Piece(s) 11 Day(s) 0.363P22-

-

1 Piece(s) 11 Day(s) 0.384P22-

-

1 Piece(s) 11 Day(s) 0.3105P22-

-

1 Piece(s) 11 Day(s) 0.3--22-

-

1 Piece(s) 11 Day(s) 0.3-13P22-

-

1 Piece(s) 11 Day(s) 0.34020P22-

-

1 Piece(s) 11 Day(s) 0.35025P22-

-

1 Piece(s) 11 Day(s) 0.521P205.1

-

1 Piece(s) 11 Day(s) 0.542P20-

-

1 Piece(s) 11 Day(s) 0.563P20-

-

1 Piece(s) 34 Day(s) 0.584P20-

-

1 Piece(s) 11 Day(s) 0.5105P20-

Loading...

  1. 1
 

Basic Information

Shield Present Sheath (outer coating) color Black Grounding Wire None
Properties Heat resistance / Chemical resistance Sheath (outer coating) material PVC Insulation body materials PVC
Electroplating Tin Maximum Voltage 500V/5min Twisting Structure Stranded Wire
Part Number Twisted-Pair Intended Use Signal
  • The specifications and dimensions of some parts may not be fully covered. For exact details, refer to manufacturer catalogs .