(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

  • Notice of End of Sales for Economy Series Pneumatic Equipment Category. More information. 
  • Please note that E-Invoice will be sent to our customers by email. For more information, please read News. 

KDFSB UL Standard with Shield (Part Numbers)

KDFSB UL Standard with Shield

Click this image to zoom it.

Move the mouse over the image to zoom

300 V UL Mobile Signals Cable with Shield

  • c-UL
  • VW-1
  • ULAWM
  • ULLISTED
  • Oil-Resistant
  • Strand Wire
  • Thinned Wire Conductor
  • Single Shield
  • Twisted Pair
  • 300 V

● It has especially good performance under mobile applications.

· This product is compatible with "UL Traceability Program / Processed Wire." (c-UL is not compatible)
* For cables in stock, please keep in mind that because we cut them to the specified size, they cannot be canceled or returned.

The Electrical Appliance and Material Safety Law certificate has not been obtained.

PDF

Part Number

Configured Part Number is shown.

KDFSB-0.2-6P-[1-99/1]

Specifications

KDFSB UL Standard with Shield:Related Image
* Before ordering, confirm that the following symbols in the order (if any) are correct: "( = single-byte bracket"; "1 = One"; "I = i"; "0 = zero"; "O = oh". 

1 Piece Unit 1 Roll Unit

Model NumberSection Area (mm2)Number of Pairs *3
1P = 2 Cores
Total Length
or
Specified Length
(m)
KDFSB0.21P1
~
100
(Specify 1 m
Increment)
2P
3P
5P
6P
8P
10P
15P
20P
0.31P
2P
3P
5P
6P
8P
10P
15P
20P
0.51P
2P
3P
5P
6P
8P
10P
15P
20P


Be sure to read the following precautions when you place an order.
* Length in "m" is included in our model numbers. Always specify quantity as number of units, not as meters.
* For the latest information regarding standard unit price, quantity slide unit price, shipment days, etc., refer to the Misumi VONA e-catalog.
* 1 Stock products are indicated with T or A in the price column at right.
* 2 All unit prices above are per meter.
Unit Price Calculation Method [Formula: Last digits of model number (m) x unit price per meter above]
* 3 Check the indications for number of cores, pair number, core / pair number, and pair number / core when ordering. (Check the Specification Table for number of wire cores) 1P (1PS) is "x 2-core".

More Information

KDFSB UL Standard with Shield:Related ImageKDFSB UL Standard with Shield:Related Image

KDFSB UL Standard with Shield:Related ImageKDFSB UL Standard with Shield:Related Image
KDFSB UL Standard with Shield:Related Image

Specifications

Model NumberSection Area
(mm2)
Number of Pairs *1
1P = 2 Cores
Total Length
(m)
AWG
Estimated
Size *2
Twisted
Structure
(See Figure)
Number of
Wire Cores
Finished *5
Outer Diameter
(mm)
Approximate
Mass
kg/km
Electrical PropertiesConductorInsulationWire Core
Outer Diameter
Approx. (mm)
SheathSpecificationSample
Provided
Allowable Current
A (30°C) *3
Conductor Resistance
Ω / km (20°C)
Insulation Properties
MΩkm (20°C)
Withstand Voltage
V / Min
Structure
Strands / mm
Outer Diameter
Approx. (mm)
Plating *4Thickness
(mm)
Material *4Thickness
(mm)
Material *4
KDFSB0.21P1
~
100
(Specify
1 m
Increment)
25Twisted Pair24.0236105 or less1,500 or moreAC
2000
40/0.08
Tin Plated
Annealed Copper Composite
Wire
0.6Tin0.2Fluorine (ETFE)1.00.7PVCULAWM2103
CM
-
2P46.25051.0-
3P66.75541.0ULAWM2517
CM
-
5P107.78041.0-
6P128.29041.0-
8P169.311531.0-
10P2010.51352.01.0-
15P3011.51702.01.1-
20P4012.521521.2-
0.31P2324.629871.5 or less1,500 or moreAC
2000
3/20/0.08
Tin Plated
Annealed Copper Composite
Wire
0.80.251.30.7ULAWM2103
CM
-
2P47.36571.0-
3P67.87561.0ULAWM2517
CM
-
5P109.211051.0-
6P1210.012551.0-
8P1611.015541.0-
10P2013.020041.2-
15P3014.526541.3-
20P4016.033031.4-
0.51P2025.4401143.4 or less1,500 or moreAC
2000
3/33/0.08
Tin Plated
Annealed Copper Composite
Wire
1.10.251.60.8ULAWM2103
CM
-
2P48.28591.0-
3P69.411081.0ULAWM2517
CM
-
5P1011.516071.1-
6P1212.518571.2-
8P1614.024061.3-
10P2016.532561.4-
15P3017.539551.5-
20P4020.049551.6-


*1 Please note that when the indicated Core / Pair is 1P (1PS), the number of wire cores will be "x 2-core".
*2 The size conversion is for reference only. Refer to the comparison table on >>Click here for details.
*3 The value of allowable current is to be used only as a reference value and is not guaranteed.
*4 How to View Materials
[Plating] Tin... Tin Plated Annealed Copper Wire
[Materials] PVC... Polyvinyl Chloride; PE... Polyethylene-based Material;
P... Polyester-based Material; Fluorine... Various Fluorine Resins; *... Other
*5 For the outer diameter size of cables, wire sheath (coat), etc., refer to
"Finished Outer Diameter" in the table above. 

Current Reduction Factor
Ambient Temperature (°C)30405060708090100
Current Reduction Factor1.000.930.860.770.680.580.450.26
Allowable current value indicates the calculated value of 1 cable laid aboveground in ambient temperature of 30°C, and is not a guaranteed value.
If the ambient temperature is 30 °C or above, the above current reduction factor is multiplied by the allowable current.
(Example) Allowable current value 6 x 0.93 = 5.58 (A) when the ambient temperature is 40°C at 1P 0.2mm2

Part Number
KDFSB-0.2-6P-[1-99/1]
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipOverall Length
(m)

-

1 Piece(s) Quote 1 ~ 99

Loading...

  1. 1

Basic Information

Conductor Cross Section(mm2) 0.2 Number Of Cores(Core) 12 Logarithm 6

Additional Products in this Category

Customers Who Viewed This Item Also Viewed

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:(60) 3 7890 6399
9:00am - 6:00pm (Monday - Friday)
9:00am - 1:00pm (Saturday)