UL2464FASB UL Standard with Shield (Part Numbers)

UL2464FASB UL Standard with Shield

Click this image to zoom it.

Move the mouse over the image to zoom

300 V UL Mobile Signals Cable with Shield

  • VW-1
  • ULAWM
  • Strand Wire
  • Thinned Wire Conductor
  • Single Shield
  • Twisted Pair
  • 300 V

● It uses a copper foil shield for excellent shield bending performance.

· This product is compatible with "UL Traceability Program / Processed Wire." (c-UL is not compatible)

Electrical Appliance and Material Safety Law certificate has not been obtained.

PDF

Part Number

Configured Part Number is shown.

Specifications

UL2464FASB UL Standard with Shield:Related Image
* Though the number of cores is marked, all sizes feature twisted pair stranding.
* Before ordering, confirm that the following symbols in the order (if any) are correct: "( = single-byte bracket"; "1 = One"; "I = i"; "0 = zero"; "O = oh".

Model NumberAWG SizeCore Number (Pair Number) * 3Total Length
or
Specified Length
UL2464FASB252 (1P)1
~
100
(Specify 1 m
Increment)
4 (2P)
6 (3P)
8 (4P)
10 (5P)
12 (6P)
16 (8P)
20 (10P)
232 (1P)
4 (2P)
6 (3P)
8 (4P)
10 (5P)
12 (6P)
16 (8P)
20 (10P)
202 (1P)
4 (2P)
6 (3P)
8 (4P)
10 (5P)


Be sure to read the following precautions when you place an order.
* Length in "m" is included in our model numbers. Always specify quantity as number of units, not as meters.
* For the latest information regarding standard unit price, quantity slide unit price, shipment days, etc., refer to the Misumi VONA e-catalog.
* 1 Stock products are indicated with T or A in the price column at right.
* 2 All unit prices above are per meter.
Unit Price Calculation Method [Formula: Last digits of model number (m) x unit price per meter above]
* 3 Check the indications for number of cores, pair number, core / pair number, and pair number / core when ordering.

More Information

UL2464FASB UL Standard with Shield:Related ImageUL2464FASB UL Standard with Shield:Related Image

UL2464FASB UL Standard with Shield:Related Image
UL2464FASB UL Standard with Shield:Related Image
UL2464FASB UL Standard with Shield:Related Image

Specifications

Model NumberAWG
Size
Number of CoresEstimated
Section Area
( mm2) *1
Twisted
Structure
(See Figure)
Pair Core
Number of Wires
Finished *5
Outer Diameter
(mm)
Approximate
Mass
kg/km
Electrical PropertiesConductorInsulationWire Core
Outer Diameter
Approx. (mm)
SheathSpecificationSample
Provided *4
Allowable Current
A (30°C) *2
Conductor Resistance
Ω / km (20°C)
Insulation Properties
MΩkm (20°C)
Withstand Voltage
V / Min
Structure
Strands / mm
Outer Diameter
Approx. (mm)
Plating *3Thickness
(mm)
Material *3Thickness
(mm)
Material *3
UL2464FASB2520.2Twisted Pair2 (1P)4.7263.58105 or less1000
or more
200040/0.080.58Tin0.2Fluorine (ETFE)0.981.0PVCULAWM2464-
44 (2P)6.3442.77-
66 (3P)6.6502.34-
88 (4P)7.1602.05-
1010 (5P)7.6701.91-
1212 (6P)8751.62-
1616 (8P)9.11001.43-
2020 (10P)10.21201.43-
2320.32 (1P)5304.769.5 or less60/0.080.720.21.12-
44 (2P)6.9513.63-
66 (3P)7.2603.07-
88 (4P)7.7712.69-
1010 (5P)8.3852.5-
1212 (6P)8.8952.13-
1616 (8P)10.11251.88-
2020 (10P)11.31501.88-
2020.52 (1P)5.5516.9740.1 or less104/0.080.940.251.44-
44 (2P)8755.39-
66 (3P)8.5954.55-
88 (4P)9.21154-
1010 (5P)9.91353.72-


*1 The size conversion is for reference only. Refer to the comparison table on >>Click here for details.
*2 The value of allowable current is to be used only as a reference value and is not guaranteed.
*3 How to View Materials
[Plating] Tin... Tin Plated Annealed Copper Wire
[Materials] PVC... Polyvinyl Chloride; PE... Polyethylene-based Material;
P... Polyester-based Material; Fluorine... Various Fluorine Resins; *... Other
*4 For the outer diameter size of cables, wire sheath (coat), etc., refer to
"Finished Outer Diameter" in the table above. 
 
Current Reduction Factor
Ambient Temperature (°C)3040506070
Current Reduction Factor1.000.900.780.640.45
Allowable current value indicates the calculated value of 1 cable laid aboveground in ambient temperature of 30°C, and is not a guaranteed value.
If the ambient temperature is 30 °C or above, the above current reduction factor is multiplied by the allowable current.
(Example) Allowable current value 3.58 x 0.90 = 3.222 (A) when the ambient temperature for 2-core AWG25 is 40 °C

Part Number
UL2464FASB-23-4-[1-100/1]
UL2464FASB-23-6-[1-100/1]
UL2464FASB-23-8-[1-100/1]
UL2464FASB-25-4-[1-100/1]
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipOverall Length
(m)
Conductor Cross Section
(mm2)
AWG size
(AWG)
Number Of Cores
(Core)
Logarithm Finished outer diameter
(mm)
Rated Voltage Shield Representative Standard Sheath (outer coating) color Sheath (outer coating) material Insulation body materials Other properties

-

1 Piece(s) 3 Day(s) or more 1 ~ 1000.3-42--------

-

1 Piece(s) 3 Day(s) or more 1 ~ 1000.3-63--------

-

1 Piece(s) 4 Day(s) or more 1 ~ 1000.323847.7300V[Available] PresentULBlackPVCFluorineElastic, Vibration-resistant

-

1 Piece(s) 3 Day(s) or more 1 ~ 1000.2-42--------

Loading...

  1. 1

Additional Products in this Category

Customers Who Viewed This Item Also Viewed

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:(60) 3 7890 6399
9:00am - 6:00pm (Monday - Friday)